Sirolimus-Coated Versus Paclitaxel-Coated Balloons for Coronary Artery Disease: A Grade Assessed Systematic Review and Meta-Analysis
Loading...
Contact
Check for full-text access
Issue Date
Type
Journal article
Language
Keywords
Alternative Title
Abstract
Despite advances in percutaneous coronary procedures, in-stent restenosis remains a significant challenge. Although sirolimus- and paclitaxel-coated balloons are promising alternatives, their comparative safety and efficacy remain uncertain. PubMed, Embase, and Cochrane databases were searched using relevant keywords from inception until August 2025. A total of 11 studies (7 randomized controlled trials and 4 observational cohort studies) were included, comprising 3633 participants overall. The primary outcomes assessed were target lesion revascularization and target lesion failure. Meanwhile, the Secondary outcomes included stent thrombosis, all-cause mortality, myocardial infarction, major adverse cardiovascular events, survival, binary restenosis, and angiographic endpoints (acute gain, diameter stenosis, in-segment late lumen loss, in-lesion late lumen loss, and in-segment minimal lumen diameter). Interstudy heterogeneity was assessed using I² and X² statistics (I²>50% = significant heterogeneity). Interstudy heterogeneity was low for most outcomes, including all primary clinical endpoints, with moderate heterogeneity observed only for select angiographic measures (notably in-segment late lumen loss and diameter stenosis). Statistical analysis was conducted using R software and RStudio (version 4.4.2), with a P value of < 0.05 indicating statistical significance. This meta-analysis examined studies that compared paclitaxel-coated balloon (PCB) versus standard balloon [sirolimus-coated balloon (SCB)] angioplasty. Regarding primary outcomes, there were no notable variations in target lesion failure [risk ratio (RR), 1.08, 95% CI, 0.90–1.29, P = 0.36] or target lesion revascularization (RR, 1.16, 95% CI, 0.98–1.37, P = 0.08). With all aggregated estimates being nonsignificant, secondary outcomes such as stent thrombosis, all-cause mortality, myocardial infarction, major adverse cardiovascular events, and survival were similar between groups. Angiographic endpoints revealed no discernible variations in late lumen loss (in-lesion and in-segment), acute gain, or diameter stenosis. Nonetheless, the SCB group’s minimal lumen diameter was significantly smaller than that of the PCB group (MD, −0.08 mm, 95% CI, −0.14 to −0.01, P = 0.02). In treating coronary in-stent restenosis, SCB and PCBs show similar overall safety and effectiveness; lesion-specific angiographic variations indicate that customized selection may improve patient outcomes.
Description
Citation
Sajjad F, Khattak AI, Farhan K, Arshad A, Afridi A, Ali MA, Shahid I, Imtiaz Z, Naveed H, Alam U, Henna F, Riaz Z, Khattak F, Waqas SA, Ahmed R. Sirolimus-Coated Versus Paclitaxel-Coated Balloons for Coronary Artery Disease: A Grade Assessed Systematic Review and Meta-Analysis. Crit Pathw Cardiol. 2026 Jun 1;25(2):e0415. doi: 10.1097/HPC.0000000000000415. Epub 2026 Jan 14. PMID: 41533835; PMCID: PMC13193178.
Publisher
License
Journal
Critical Pathways in Cardiology
Volume
25
Issue
2