An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size
Loading...
Contact
Check for full-text access
Issue Date
Type
Article
Language
Keywords
Alternative Title
Abstract
This study aims to assess the accuracy of CT imaging in estimating intraocular foreign body (IOFB) size by comparing pre-operative radiological measurements with post-surgical dimensions. A retrospective review of 12 cases over 9 years at a UK tertiary centre. IOFB size on CT imaging was compared with post-surgical measurements. Soft tissue window CT overestimated IOFB size (p=0.025). Bone window CT was more accurate but still varied, with one-third differing by>50% to definitive size. We conclude that caution is needed in CT-based IOFB size estimation. Plain radiographs may provide additional accuracy.
Description
Citation
Publisher
License
Journal
The British journal of ophthalmology
Volume
109
Issue
Issue
